FMGCG Marine Communication Cable


Standard : DIN 89159 

Cable Construction 

1.Conductor:Annealed Standard Copper,Class 2. 

2.Insulation:EPR(Cross-linked Ethylene Propylene Rubber) 

3.Laying Up:Pair stranding(2 pair cable=quad stranding) 

4.Armour:Separator tape,bare copper braid 

5.Outer sheath : Cross-linked Polychloroprene Rubber,Black. 

Applications 

1.For fixed installations in communication,radio,control,data processing facilities on ship and offshore. 

2.The ship cable meet the flame test requirements for bunched.(IEC 60332-3,IEEE 45-18.13) 

Electrical Characteristics 

1.Rated Voltage Uo/U(Um):150/250V 

2.Test Voltage:1500V 

Usage Characteristics 

1.Max.Conductor temperature in service:85 °C 

2.Short-circuit max.conductor temperature:250 °C 

3.Minimum installation temperature:–10 °C 

4.Minimum operating temperature:–35 °C 

5.Flame retardant:IEC 60332-3 Cat. A 

6.Smoke Density:IEC 61034 

7.Gases corrosivity:IEC 60754-2 

8.Gases toxicity:No toxicity to IEC 60754-1 

9.Electro magnetic interference resistance:YES 

10.Minimum internal bending radius:6×cable Diameter

Product No. Pair No. Cross Section Outer Diameter Approx.Weight
(mm²) Min(mm) Max(mm) kg/km
FMGCG01 1 0.75 7.5 9 120
FMGCG02 10 0.75 17.5 19.5 580
FMGCG03 14 0.75 19.5 22.5 740
FMGCG04 19 0.75 22 26 930
FMGCG05 2 0.75 8.5 10 170
FMGCG06 24 0.75 25 28.5 1200
FMGCG07 4 0.75 12 13.5 290
FMGCG08 7 0.75 15 17 410



Contact with us now