YLG-0.30 Marine Hydrophore Tank
1. YLG-0.30 Marine Hydrophore Tank Technical Requirements:
(1) Flange Standard:CB/T46-1999 PN1.0;
(2) The shell cover thickness including the forming thinning;
(3) The system including security settings;
(4) Pipes and support same as the drawings.
2. YLG-0.30 Marine Hydrophore Tank Outer Joint
|
Mark |
Name |
Size |
Standard |
|
a |
relief outlet |
3/4' |
|
|
b |
Water Inlet |
DN32 |
CB/T46-1999 PN1.0 |
|
c |
Compressor Air Inlet |
3/8' |
CB*53-80 |
|
d |
Water Outlet |
DN32 |
CB/T46-1999 PN1.0 |
|
Working Pressure |
0.6Mpa |
|
Design Pressure |
0.7Mpa |
|
Working Temp. |
0~45℃ |
|
Design Temp. |
50℃ |
|
Main Materials |
CCS-B/SS304/SS316 |
|
corrosion allowance |
0.75mm |
|
welded joint coefficient |
0.6 |
|
Capacity |
0.3m³ |
|
The relief valve pressure jump |
0.63MPa |
|
G.W. |
265 Kgs (with standard export wooden case) |
|
N.W. |
215 Kgs |