600 m³ Ballast Water Management Plant
Application
The ship ballast water management system adopts a pure physical treatment method of filtration + nitrogen to treat the ballast water discharged from the ship to the sea. It has the advantages of easy installation, easy operation, safety and reliability, environmental protection and pollution-free.
Treatment Technology
Mechanical filtration - high pressure back flush to ensure flux;
Type
TRC (m3/h)
Configuration power (kW)
Salinity
Water temperature
Ambient temperature
Compressed air pressure
Flow rate
NB-600
600
13.4
No limitation
No limitation
0~55℃
0.7MPa
No limitation
Membrane separation - reducing sediments and delaying cleaning;
Nitrogen feeding and de-oxygenation - kill organisms and prevent corrosion.
Composition
1.Filter Units
It is used to remove organisms and solid particles greater than 50μm, and carry out High pressure and suction back flushing of the filter core under differential pressure or timer.
2.Membrane Separation unit
It is used to remove organisms and solid particles greater than10μm, and performing gas-water mixture back flush on the membrane elements under the control of differential pressure or timer.
3.Nitrogen Generator
The nitrogen generator uses air as the material and uses molecular sieves to selectively adsorb nitrogen and oxygen.
4.Control Unit
It has Automatic and manual control system operation, used to monitor the operation status of the system and record system operation information.
Treatment Flow
IACS Certificate Options: BV, CCS, NK, DNV. GL, IRS, ABS, LR, RMRS, RINA