A60 Ship Pneumatic Fire Damper - Marine Fire Damper - Hi-sea

A60 Ship Pneumatic Fire Damper

A60 Ship Pneumatic Fire Damper

1. Features
The fire damper should normal open on getting compressed air&electric power, and should be close on loss of compressed air or electric power. Pneumatic operating pressure is 0.5-0.8MPa;
If the temperature of air in damper duct exceeds 70±3℃, the fusible link if fire damper will be broken and the change valve will cut off the compressed air source to close the fire damper;
On/off status of control electric source for solenoid change valve should be controlled locally or remotely, thus open/close the fire damper;
Manual change valve can be controlled by handle dragline, and the fire damper can close locally or remotely;
on/off signal output when the fire damper is on/off.
2. Types & parameter

Control method

Pneumatic+manual+overtemperature shutdown

Control unit

Electric actuator

voltage

AC24-240V, 50/60Hz DC24-125V

Air source

0.55-0.8 MPa

Installation type

Bulkhead type/deck type

Fire resistance rating

A0/A15/A30/A60

Control mode

Local/remote/central control

Switch working angle of valve plate

0°,90°

Switch indication

Mechanical/remote open or close signal

Turn-off time

2s

Overtemperature shutdown

70±3

Air-tightness

Hermetic/non-Hermetic

Air leakage

Hermetic: meet EN1751: 1998 standard

Non-Hermetic: meet CB/T3557-1995 standard

Spindle material

Stainless steel

Explosion-proof requirement

Explosion-proof/non-explosion-proof

Level of protection

IP67

Valve body color

Red(standard) or users define

Model

Hermetic: rectangle/rectangle to round

Non-Hermetic: rectangle/round/rectangle to round

Note: Flange size of all fire damper could be fabricatede according to user's requiremnet.
3. Supply scope
1) electrical control box     1 set
2) junction box               1 set
3) pneumatic actuator system  1 set
4) The material of cylinder should be aluminum alloy or stainless steel according to user's requirement.
4. Outline drawing

Marine Pneumatic Fire DamperMarine Pneumatic Fire Damper
5. IACS Certificate: KR, LR, CCS, CE, DNV▪GL, BV, ABS